TankAtlas Australia For suppliers
Tank finder Calculators States & rules Tank sizes Tank types Delivery & install Suppliers Rebates For manufacturers and stockists

Calculators

Five calculators, one tank decision

Each one uses published manufacturer guidance or state rules. Assumptions are named next to the result.

01

Tank size

Recommended storage

9,500 L

Roof harvest per year
174,672 L
Use per year
105,850 L
Use covered by rain
100%
Storage for 30 dry days
8,700 L

1 mm of rain on 1 m² of roof gives 1 litre (YourHome). We count 80% to allow for the first flush and overflow, our assumption. The 60 L/day toilet and laundry figure is an estimate; 247 L/day is the NSW BASIX benchmark (source). For a daily simulation use Renew's Tankulator.

02

Foundation

Pad size

Ø 2.45 m

Pad area
4.7 m²
Depth
100 mm
Material volume
0.47 m³
Load when full
5.0 t

Compacted sand or crusher dust 75 to 100 mm with edging, or a 75 to 100 mm concrete pad.

Rule: Coerco installation guide. 1 litre of water weighs 1 kg. Order 10 to 15% extra material for compaction, our assumption.

03

Bushfire static water

Static water required

10,000 L

Material
Concrete or metal, above ground
Fittings
64 mm CFA 3 thread per inch male coupling, gravity feed, CFA access

Bushfire Management Overlay single dwelling measures. Swimming pools and dams do not count. Source. Your permit or consent conditions always decide.

04

Delivery and crane check

Wires, branches, eaves.

Placement

Roll it in

  • ok Path width 3 m vs 2.86 m needed to roll the tank on its side
  • ok Clearance 5 m vs 4.08 m tank diameter plus margin
  • ok Slope 5% (rolling over 10% is risky)
  • ok Distance 25 m (over 60 m means a long roll)
Helpers to have on site
2+
Weight empty, approx.
470 kg

Drivers need able-bodied helpers and will not unload without safe access (ASC). A crane is at the buyer's expense (Bushmans). Put about 25 mm of water in an empty tank to stop it blowing away (Bushmans). The width, slope, distance, helper and empty weight thresholds are our rules of thumb.

05

Total installed cost

Check the seller's freight charge for your postcode.

Installed estimate

$2,795 to $4,900

Tank
$1,295 to $1,400
Base, plumbing, pump
$1,500 to $3,500
Delivery
$0
Rebate
−$0

Tank price: Duraplas R5000sq $1,295 on sale, was $1,350 (Ø 2.175 × 1.75 m); R5000ur $1,400 (Ø 1.80 × 2.47 m). The base, plumbing and pump ranges are our planning assumptions, not quotes; replace them with your installer's quote. See listed models.